AMCC 720-0140-00 Guía de instalación

Busca en linea o descarga Guía de instalación para Los controladores raid AMCC 720-0140-00. AMCC 720-0140-00 Installation guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 93
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
3ware
®
Serial ATA RAID Controller
Command Line Interface
Supports the 9590SE-4ME for the Power Mac® G5
PN: 720-0140-00
September 2006
CLI Guide for the Power Mac G5
Vista de pagina 0
1 2 3 4 5 6 ... 92 93

Indice de contenidos

Pagina 1 - Serial ATA RAID Controller

3ware® Serial ATA RAID ControllerCommand Line Interface Supports the 9590SE-4ME for the Power Mac® G5PN: 720-0140-00September 2006CLI Guide for the Po

Pagina 2 - Disclaimer

Chapter 1. Introduction to the 3ware Command Line Interface4 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5Supported Operating System

Pagina 3 - Table of Contents

Installing the 3ware CLI on Mac OS Xwww.3ware.com 5Installing the 3ware CLI on Mac OS X3ware CLI can be installed from the 3ware software CD, or the

Pagina 4

Chapter 1. Introduction to the 3ware Command Line Interface6 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5Using the command interfac

Pagina 5

Working with 3ware CLIwww.3ware.com 7Using an input file to execute a scriptYou can operate 3ware CLI scripts by executing a file. The file is a text

Pagina 6

Chapter 1. Introduction to the 3ware Command Line Interface8 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5ConventionsThe following c

Pagina 7 - About this CLI Guide

Understanding RAID Levels and Conceptswww.3ware.com 9RAID ConceptsThe following concepts are important to understand when working with a RAID control

Pagina 8

Chapter 1. Introduction to the 3ware Command Line Interface10 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5Available RAID Configurat

Pagina 9 - Command Line Interface

Understanding RAID Levels and Conceptswww.3ware.com 11Figure 1. RAID 0 Configuration Example RAID 1RAID 1 provi

Pagina 10 - Terminology

Chapter 1. Introduction to the 3ware Command Line Interface12 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5Figure 3. RAID 5 Configu

Pagina 11 - Working with 3ware CLI

Understanding RAID Levels and Conceptswww.3ware.com 13Single DiskA single drive can be configured as a unit through 3ware software. (3DM 2 or CLI). L

Pagina 12 - Example

www.3ware.com iiCopyright ©2003-2006 Applied Micro Circuits Corporation (AMCC). All rights reserved. This publication may be copied or reproduced for

Pagina 13 - Scripting example

Chapter 1. Introduction to the 3ware Command Line Interface14 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5Using Drive Capacity Effi

Pagina 14 - Conventions

www.3ware.com 152CLI Syntax Reference This chapter provides detailed information about using the command syntax

Pagina 15 - RAID Concepts

Chapter 2. CLI Syntax Reference16 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5 Table 4: Commo

Pagina 16 - Available RAID Configurations

Common Tasks Mapped to CLI Commandswww.3ware.com 17Add a time slot to a verify schedule/cx add verify 46Add a time slot to a selftest schedule/cx add

Pagina 17

Chapter 2. CLI Syntax Reference18 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5Syntax OverviewThe command syntax uses the general fo

Pagina 18

Shell Object Commandswww.3ware.com 19Port Object Commands. Port object commands provide information and perform actions related to a drive on a speci

Pagina 19 - Hot Spare

Chapter 2. CLI Syntax Reference20 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5if you set the focus to //hostname/c0/u0, the prompt

Pagina 20

Shell Object Commandswww.3ware.com 21(Not Optimal) state, RRate (Rebuild Rate) of 2, VRate (Verify Rate) of 5, BBU of '-' (Not Applicable).

Pagina 21 - CLI Syntax Reference

Chapter 2. CLI Syntax Reference22 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5show alarms [reverse]This command shows the alarms or

Pagina 22

Shell Object Commandswww.3ware.com 23show verifyThis command displays all verify schedules for the 9000 controllers in the system. Example://localhos

Pagina 23

www.3ware.com iiiTable of ContentsChapter 1. Introduction to the 3ware Command Line Interface . . . . . . .3Features of the CLI . . . . . . . . . . .

Pagina 24 - Syntax Overview

Chapter 2. CLI Syntax Reference24 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5flushThis command sends a flush command to all 3ware

Pagina 25 - Shell Object Commands

Controller Object Commandswww.3ware.com 25Controller Object CommandsController object commands provide information and perform actions related to a s

Pagina 26 - Example:

Chapter 2. CLI Syntax Reference26 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx set verify=enable|disable|1..5 (9000 only)/cx se

Pagina 27

Controller Object Commandswww.3ware.com 27Typical output looks like: //localhost> /c0 showUnit UnitType Status %Cmpl Stripe Size(GB) Cach

Pagina 28

Chapter 2. CLI Syntax Reference28 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx show driverThis command reports the device driver

Pagina 29

Controller Object Commandswww.3ware.com 29/cx show serialThis command reports the serial number of the specified controller /cx. Example: //localhost

Pagina 30 - [force]

Chapter 2. CLI Syntax Reference30 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx show numportsThis command reports the port capaci

Pagina 31 - Controller Object Commands

Controller Object Commandswww.3ware.com 31/cx show spinupThis feature only applies to 9000 series controllers.This command reports the number of conc

Pagina 32

Chapter 2. CLI Syntax Reference32 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5For operating systems that support units larger than

Pagina 33

Controller Object Commandswww.3ware.com 33/cx show autorebuildThis feature only applies to 9550SX and 9590SE model controllers.This command shows the

Pagina 34

iv 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx show numdrives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 35

Chapter 2. CLI Syntax Reference34 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx show allunitstatusThis command presents a count o

Pagina 36

Controller Object Commandswww.3ware.com 35/cx show allThis command shows the current setting of all of the following attributes on the specified cont

Pagina 37

Chapter 2. CLI Syntax Reference36 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx add type=<RaidType> disk=<p:-p> [stri

Pagina 38 - show memory

Controller Object Commandswww.3ware.com 37group=3|4|5|6 indicates the number of disks per group for a RAID 50 type. (This attribute can only be used

Pagina 39 - show unitstatus

Chapter 2. CLI Syntax Reference38 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5 name=string att

Pagina 40 - show drivestatus

Controller Object Commandswww.3ware.com 39/cx commit This command only applies to the Windows operating system. It commits all changes if a faster sh

Pagina 41 - show all

Chapter 2. CLI Syntax Reference40 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5 Recommendation: No need to update. Given the above r

Pagina 42 - Example: type=raid5

Controller Object Commandswww.3ware.com 41In order to redirect the output you must run the following command from a command line, not from within the

Pagina 43 - For the 7/8000

Chapter 2. CLI Syntax Reference42 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5If the rebuild schedule is enabled while a rebuild pr

Pagina 44 - rescan [noscan]

Controller Object Commandswww.3ware.com 43 p9 OK u0 74.53 GB 156301488 3JV3WRHC p10 OK u0 74.53 GB

Pagina 45

www.3ware.com v/cx/ux show name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55/cx/ux show serial . . . .

Pagina 46 - show diag

Chapter 2. CLI Syntax Reference44 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx show selftest9000 series controllers support back

Pagina 47 - show rebuild

Controller Object Commandswww.3ware.com 45/cx add rebuild=ddd:hh:durationThis command adds a new background rebuild task to be executed on the day dd

Pagina 48

Chapter 2. CLI Syntax Reference46 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx add verify=ddd:hh:durationThis command adds a new

Pagina 49 - show verify

Controller Object Commandswww.3ware.com 47/cx add selftest=ddd:hhThis command adds a new background selftest task to be executed on the day ddd (wher

Pagina 50 - show selftest

Chapter 2. CLI Syntax Reference48 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx del verify=slot_idThis command removes the verify

Pagina 51 - Setting Up a Rebuild Schedule

Controller Object Commandswww.3ware.com 49/cx set verify=enable|disable|1..5This command enables or disables all verify background task slots on cont

Pagina 52 - Setting Up a Verify Schedule

Chapter 2. CLI Syntax Reference50 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx set ondegrade=cacheoff|followThis command is only

Pagina 53 - del rebuild=

Controller Object Commandswww.3ware.com 51volume. Each volume can then be treated as an individual disk with its own file system. The default carvesi

Pagina 54

Chapter 2. CLI Syntax Reference52 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5having to specify it as a spare. It also means that i

Pagina 55

Unit Object Commandswww.3ware.com 53Unit Object CommandsUnit Object commands provide information and perform actions related to a specific unit, such

Pagina 56

vi 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx/bbu show pcb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 57 - set autorebuild=on

Chapter 2. CLI Syntax Reference54 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5One application of the /cx/ux show command is to see

Pagina 58 - stop mediascan

Unit Object Commandswww.3ware.com 55/cx/ux show rebuildstatusThis command reports the rebuildstatus (if any) of the specified unit. Example: //localh

Pagina 59 - Unit Object Commands

Chapter 2. CLI Syntax Reference56 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx/ux show qpolicyThis feature only applies to 9550S

Pagina 60

Unit Object Commandswww.3ware.com 57/cx/ux show cacheThis command shows the current write cache state of the specified unit.Example://localhost> /

Pagina 61

Chapter 2. CLI Syntax Reference58 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5 u1-2 DISK OK - - p2 -

Pagina 62

Unit Object Commandswww.3ware.com 59noscan is used to not inform the operating system of this change. The default is to inform the operating system.

Pagina 63

Chapter 2. CLI Syntax Reference60 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5 When you issue

Pagina 64

Unit Object Commandswww.3ware.com 61/cx/ux flushThis command allows you to flush the write cache on the specified unit /ux associated with controller

Pagina 65

Chapter 2. CLI Syntax Reference62 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx/ux set identify=on|offThis feature only applies t

Pagina 66

Unit Object Commandswww.3ware.com 63By default, qpolicy is off.Example://localhost> /c0/u5 set qpolicy = onSetting Command Queuing Policy for unit

Pagina 67

www.3ware.com 1About this CLI Guide3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5 provides instructions for configuring and maintain

Pagina 68

Chapter 2. CLI Syntax Reference64 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5• Write journaling is disabled, if no BBU is present,

Pagina 69

Unit Object Commandswww.3ware.com 65 type=RaidType specifies the RAID type of the destination unit. Possible uni

Pagina 70 - RaidType

Chapter 2. CLI Syntax Reference66 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5group=3|4|5|6 indicates the number of disks per group

Pagina 71

Unit Object Commandswww.3ware.com 67autoverify attribute enables the autoverify attribute on the unit that is to be migrated. For more details on thi

Pagina 72 - 256 256 256

Chapter 2. CLI Syntax Reference68 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5//localhost> /c0/u0 migrate type=raid10 disk=2-3 s

Pagina 73 - Example of migrate output

Port Object Commandswww.3ware.com 69Port Object CommandsPort Object Messages are commands that provide information and perform actions related to a s

Pagina 74

Chapter 2. CLI Syntax Reference70 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx/px show statusThis command displays the status of

Pagina 75 - Port Object Commands

Port Object Commandswww.3ware.com 71/cx/px show ncqThis command applies only to 9550SX and 9590SE model controllers.This command displays the NCQ (Na

Pagina 76

Chapter 2. CLI Syntax Reference72 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5Example://localhost> /c0/p5 show smart/c0/p5 Drive

Pagina 77

Port Object Commandswww.3ware.com 73/cx/px remove [noscan] [quiet]This command allows you to remove (or export) a port (or drive) /cx/px. Exporting a

Pagina 78

2 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5

Pagina 79

Chapter 2. CLI Syntax Reference74 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5BBU Object CommandsBBU (Battery Backup Unit) Object C

Pagina 80 - BBU Object Commands

BBU Object Commandswww.3ware.com 75/cx/bbu show attribute [attribute ...]This command shows the current setting of the given attribute(s) on the BBU

Pagina 81 - attribute

Chapter 2. CLI Syntax Reference76 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/cx/bbu show batinstThis command shows the date when

Pagina 82

BBU Object Commandswww.3ware.com 77/cx/bbu show serialThis command shows the BBU serial number. /cx/bbu show fwThis command shows the BBU firmware ve

Pagina 83

Chapter 2. CLI Syntax Reference78 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5 AEN (Asynchrono

Pagina 84 - /bbu disable [quiet]

Enclosure Object Commandswww.3ware.com 79Enclosure Object CommandsEnclosure object commands provide information and perform actions related to a spec

Pagina 85 - Enclosure Object Commands

Chapter 2. CLI Syntax Reference80 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5 TempSensor Temperature ----------------------

Pagina 86

Enclosure Object Commandswww.3ware.com 81/ex show fansThis command lists the fans in enclosure /ex and shows their status. Possible statuses are OK a

Pagina 87

Chapter 2. CLI Syntax Reference82 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5/ex/slotx show identifyThis command shows the identif

Pagina 88

Help Commandswww.3ware.com 83Help CommandsThe Help commands provides brief on-line help. You can get overview help by typing Help at the top-level pr

Pagina 89 - Help with specific commands

www.3ware.com 31Introduction to the 3ware Command Line Interface3ware RAID controllers can be managed using the CLI via a command line or script.

Pagina 90 - Help with attributes

Chapter 2. CLI Syntax Reference84 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5 /cx del selftest=slot_id (9000 on

Pagina 91 - Help Commands

Help Commandswww.3ware.com 85helpThis help command provide a table of contents, providing help with the overall navigation of the CLI commands. Typic

Pagina 92

Chapter 2. CLI Syntax Reference86 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5help rescanThis command provides specific rescan rela

Pagina 93 - Return Code

Return Codewww.3ware.com 87help /cx/bbuThis command provides specific /cx/bbu related help, illustrating various ways to use the /cx/bbu command. See

Comentarios a estos manuales

Sin comentarios