AMCC 720-0140-00 Guía de instalación Pagina 85

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 93
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 84
Enclosure Object Commands
www.3ware.com 79
Enclosure Object Commands
Enclosure object commands provide information and perform actions related
to a specific enclosure, such as /e0 and its elements, such as /e0/slot0.
Enclosure object elements include slot, fan, and temperature sensor elements.
These commands support the 9550SX and 9590SE controllers. If you
purchased an enclosure directly from a third-party vendor, the appropriate
EPCT (Enclosure Port Configuration Table) must have been downloaded to
the controller in order to take advantage of these commands.
If you have a 3ware Sidecar Kit for use with a Power Mac G5, the required
EPCT file is already installed.
Syntax
/ex show (9550SX and 9590SE only)
/ex show attribute [attribute ...] where attributes are:
controllers|slots|fans|temp
/ex show all (9550SX and 9590SE only)
/ex/slotx show (9550SX and 9590SE only)
/ex/slotx show identify (9550SX and 9590SE only)
/ex/slotx set identify=on|off (9550SX and 9590SE only)
/ex/fanx show (9550SX and 9590SE only)
/ex/tempx show (9550SX and 9590SE only)
/e
x
show
This command shows summary information on the specified enclosure /ex.
This report consists of four parts; the Enclosure summary listing the present
elements, a Fan summary section listing of all present fans, a Temperature
Sensor summary section listing of all present temperature sensors and a Slot
summary section listing of slots and associated information for the specified
enclosure.
Typical output looks like:
//localhost> /e0 show
Encl Controllers
-------------------------
e0 /c0
Fan Status
----------------------
fan0 OK
Vista de pagina 84