Error and Notification Messages
www.3ware.com 245
0030 Drive not supported
Event Type
Error
Cause
3ware 8000 and 9500S Serial ATA controllers only support UltraDMA-100/
133 drives when using the parallel-to-serial ATA converter. This message
indicates that an unsupported drive was detected during rollcall or a hot swap.
This message could also indicate that the parallel-to-serial converter was
jumpered incorrectly.
Action
Use a parallel ATA drive which supports UDMA 100 or 133 and check that
the parallel-to-serial converter was correctly jumpered to correspond to
UDMA 100 or 133 drives.
See Also
Refer to the User Manual for your controller.
For a list of compatible drives, see
http://www.3ware.com/products/compatibility_sata.asp
0032 Spare capacity too small
Event Type
Warning
Cause
There is a valid hot spare but the capacity is not sufficient to use it for a drive
replacement in existing units.
Action
Replace the spare with a drive of equal or larger capacity than the existing
drives.