AMCC 3WARE 9500S Guía de usuario Pagina 264

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 302
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 263
Chapter 12. Troubleshooting
254 3ware Serial ATA RAID Controller User Guide
Cause
The battery pack voltage being monitored by the Battery Backup Unit has
fallen below the warning threshold.
Action
The Battery Backup Unit is presently still able to backup the 3ware RAID
controller, but you should replace the battery pack if the warning continues.
0046 Battery voltage is high
Event Type
Warning
Cause
The battery pack voltage being monitored by the Battery Backup Unit has
risen above the warning threshold.
Action
The Battery Backup Unit is presently still able to backup the 3ware RAID
controller, but you should replace the battery pack if the warning continues.
0047 Battery voltage is too low
Event Type
Error
Cause
The battery pack voltage being monitored by the Battery Backup Unit is too
low to backup the 3ware RAID controller.
You may see this message during a battery capacity test. In this case, it is not a
sign of battery failure.
You may also see this message if the battery pack is plugged in while the
computer is on. This is not advised.
Action
Replace the battery pack if none of the above causes apply and the warning
continues.