Setting Unit Policies
www.3ware.com 123
To enable or disable queuing for a unit through 3DM
1 Choose
Management > Controller Settings from the menu bar in 3DM.
2In the
Unit Policies section of the Controller Settings page, enable
queuing by checking the box under “Queuing” for the designated unit;
disable it by unchecking the box.
The page refreshes, and a message at the top confirms the change that you
have made.
To enable or disable queuing for a unit through 3BM
1 At the main 3BM screen, select the unit by highlighting it and pressing
Enter
.
An asterisk appears in the left-most column to indicate that it is selected.
2Tab to the
Maintain Unit button and press Enter.
3 On the pop-up menu, select
Configure and press Enter.
4In the Configure Disk Array screen, Tab to the field Drive Queuing
Mode
.
5 Press
Enter
to display the choices, use the
arrow keys
to select the setting
you want (Enabled or Disabled), and press
Enter
again to choose it.
6 Tab to the OK button and press Enter to select it.
You return to the main 3BM screen.
7 When you are finished making changes, press
F8 to save them and exit
3BM.
Setting the StorSave Profile for a Unit
You can set the desired level of data protection versus performance for a unit
by selecting the StorSave Profile. Three profiles are provided: Protection
(maximum data protection), Performance (maximum performance, less data
protection), and Balanced (a middle ground). The default is Protection.
Note: Not all drives support command queuing. If a drive does not support
command queuing, the policy setting for the controller is ignored. Queuing
information for SAS is not available.