Troubleshooting
266 3ware SAS/SATA RAID Software User Guide, Version 9.5.1
To lower the likelihood of getting this error, schedule regular verifications.
See Also
“Setting Overwrite ECC (Continue on Source Error When Rebuilding)” on
page 121.
“Scheduling Background Tasks” on page 173
0005 Rebuild completed
Event Type
Information
Cause
The 3ware RAID controller has successfully completed a rebuild. The data is
now redundant.
Action
None required.
0006 Incomplete unit detected
Event Type
Warning
Cause
The 3ware RAID controller has detected an incomplete unit.
An incomplete unit is a unit in which the 3ware RAID controller is unable to
detect one or more drives. The drives may be missing, dead, or improperly
connected. A unit that is incomplete is also degraded (although a degraded
unit can be complete if all drives are still detected, including the failed drive).
Action
Check hardware connections and reseat the drives. Rescan the controller from
3DM to see if the unit has been restored. If you are able to restore the unit
before any data has been written to the unit, a rebuild will not be necessary. If
the unit remains incomplete, replace the missing or dead drives and initiate a
rebuild.