Error and Notification Messages
www.3ware.com 311
Action
If applicable, replace the failed power supply.
Contact your enclosure manufacturer for more information.
8044 Enclosure current normal
Event Type
Information.
Cause
Applies only to the 9690SA controller.
The enclosure power supply current is now back within the acceptable range.
Action
None required.
8045 Enclosure current over
Event Type
Error.
Cause
Applies only to the 9690SA controller.
The enclosure power supply amperage is higher than normal.
Action
Replace the failing power supply or remove any extra devices. This may be
caused by too many hard drives, which have exceeded the enclosure power
specifications. See your enclosure documentation or contact your enclosure
manufacturer for more details.
Too much current cannot be corrected by a UPS, although it can provide some
protection against a power surge.
8046 Enclosure current unknown
Event Type
Warning.