Error and Notification Messages
www.3ware.com 283
Cause
The migration of a unit has failed.
Migration changes can include:
Expanding capacity of a unit by adding drives.
Changing RAID levels, for example, from RAID 1 to RAID 5
Action
Review the list of events on the Alarms page for other entries that may give
you an idea of why the migration failed (for example, a drive error on a
specific port).
You may also wish to get the logs and contact technical support at
http://
www.3ware.com/support/index.asp.
For information on what error logs are
and how to collect them, see http://www.3ware.com/KB/
article.aspx?id=12278.
See Also
“RAID Level Migration (RLM) Overview” on page 128
0035 Migration completed
Event Type
Information
Cause
The migrated unit is now ready to be used.
Migration changes can include:
Expanding capacity of a unit by adding drives
Changing RAID levels, for example, from RAID 1 to RAID 5.
Action
If the capacity of the unit did not change, then you do not need to do anything
else. If the capacity of the migrated unit is larger, you will need to inform the
operating system of the change. See “Informing the Operating System of
Changed Configuration” on page 132.