AMCC 3ware 9650SE-2LP Guía de usuario Pagina 317

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 361
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 316
Error and Notification Messages
www.3ware.com 305
Cause
Applies only to the 9690SA controller.
The enclosure temperature is below the enclosure manufacturers specified
operating temperature.
Action
In general, cooler operating temperatures are good for enclosure components.
However, if the temperature is very cold, condensation can occur and cause
media errors and damage. Take steps to bring the operating environment back
within the enclosure manufacturers specifications.
Allow cold equipment to warm up gradually before powering on.
8024 Enclosure temp above operating
Event Type
Error.
Cause
Applies only to the 9690SA controller.
The enclosure temperature is above the enclosure manufacturers specified
operating temperature.
Action
Make sure that the fans are operational. Check for blocked ventilation in the
enclosure and the operating environment.
Continued operation of the enclosure at high temperatures may lead to data
loss and operational failure.
8025 Enclosure temp removed
Event Type
Warning.
Cause
Applies only to the 9690SA controller.
The temperature sensor in the enclosure has been removed or has failed and
the enclosure temperature is no longer being monitored.
Vista de pagina 316
1 2 ... 312 313 314 315 316 317 318 319 320 321 322 ... 360 361

Comentarios a estos manuales

Sin comentarios