Chapter 2. CLI Syntax Reference
94 3ware Serial ATA RAID Controller User Guide
The maximum temperature for successful use of a drive should be noted in the
documentation for the drive.
Example:
//localhost> /c0/e0 show temp
TempSensor Status Temperature Identify
--------------------------------------------------------
temp0 OK 41C(105F) Off
temp1 OK 37C(98F) Off
temp2 OK 34C(93F) Off
temp3 OK 38C(100F) Off
temp4 OK 38C(100F) Off
temp5 OK 34C(93F) Off
temp6 NOT-INSTALLED - Off
temp7 NOT-INSTALLED - Off
/cx/e
x
show all
This command is used with the 9690SA controller.
This command shows the current settings of all attributes for enclosure /cx/ex
/cx/e
x
/slot
x
show
This command is used by the 9690SA controller.
This command shows information about the specified /slotx on the specified
enclosure /ex. The slot name is followed by its status. If a slot has been
inserted with a drive and no fault has been detected, the status is OK. If the
slot is empty the status would indicate NO-DEVICE. The port that is
correlated to the slot is indicated in the next column. If no device is found in
the slot, that is indicated with a dash (-) in the Port column. The final column
shows whether “identify” is currently set for the specified slot.
Example:
//localhost> c0/e0/slot1 show
Slot Status Port Identify
----------------------------------------------------
slot1 OK /c0/p1 Yes
Vista de pagina 99