Enclosure Object Commands
www.3ware.com 95
/cx/e
x
/slot
x
show identify
This command is used by 9690SA controllers.
This command shows the identify status of the specified slot. The status can
be either on or off.
Example:
//localhost> c0/e0/slot1 show identify
/e0/slot1 Identify status = on
/c
x
/e
x
/slot
x
set identify=on|off
This command is used by 9690SA controllers.
This command causes the slot to be identified by blinking the LED associated
with it, or turns off identification of the LED for this slot.
Setting identify to on will cause the LED associated with that slot to blink.
Note: This command is equivalent to “/cx/px set identify=on|off” on page 85.
Example:
//localhost> c0/e0/slot1 set identify=on
Sending Identify request to Drive Slot c0/e0/slot0 to [on] ...
Done.
/c
x
/e
x
/fan
x
show
This command is used by the 9690SA controller.
This command shows the information about the specified fan element /fanx in
the specified enclosure cx/ex. The fan name is followed by its status. If a fan
is on and no fault has been detected, the status would indicate OK.
Example:
//localhost> /c0/e0/fan0 show
---Speed---
Fan Status State Step RPM Identify
------------------------------------------------------------
fan0 OK ON 1 2700 Off
/cx/ex/fan
x
show identify
This command is used by 9690SA controllers.
This command shows the identify status of the specified fan. The status can be
either on or off.
Example:
//localhost> c0/e0/fan1 show identify
c0/e0/fan1 Identify status = on
Comentarios a estos manuales